COP>5.0
Ultra-High Energy Efficiency
Pre-cooling dehumidification technology, no return air required (still operates efficiently when exhaust air is less than 70% of fresh air).
High-temperature chilled water (14/19°C) pre-cooling combined with heat pump dehumidification for double energy saving, reducing cooling source demand by another 30%.
The pre-cooling section intercepts dust, and the solution section performs deep sterilization, providing high-quality, healthy, and clean fresh air.
Compatible with external cooling/heating sources (chilled water 14/19°C, hot water 40/35°C), offering strong system expandability.
Modular design, easy to operate, low make-up water requirement, and low maintenance cost.
Suitable for scenarios with insufficient or no return air (hospitals, electronics factories) and areas where waste heat can be utilized.
| Unit Model | Unit |
GHRD- PF-02 |
GHRD- PF-03 |
GHRD- PF-04 |
GHRD- PF-05 |
GHRD- PF-06 |
GHRD- PF-08 |
GHRD- PF-10 |
GHRD- PF-12 |
GHRD- PF-15 |
GHRD- PF-20 |
GHRD- PF-25 |
||
| Outdoor Air Volume | m³ | 2000 | 3000 | 4000 | 5000 | 6000 | 8000 | 10000 | 12000 | 15000 | 20000 | 25000 | ||
| Cooling Capacity | kW | 41 | 62 | 83 | 104 | 124 | 166 | 207 | 249 | 311 | 415 | 518 | ||
| Dehumidification Capacity | kg/h | 41 | 62 | 82 | 103 | 123 | 164 | 205 | 246 | 308 | 410 | 513 | ||
| Heating Capacity | kw | 26 | 39 | 51 | 64 | 77 | 103 | 128 | 154 | 193 | 257 | 321 | ||
| Humidification Capacity | kg/h | 13 | 19 | 25 | 32 | 38 | 51 | 63 | 76 | 95 | 126 | 158 | ||
| Make-up Water Flow | kg/h | 15 | 23 | 30 | 38 | 45 | 61 | 76 | 91 | 114 | 152 | 190 | ||
| Pre-cooling/heating Coil |
Chilled Water Temperature |
℃ | 14/19 | 14/19 | 14/19 | 14/19 | 14/19 | 14/19 | 14/19 | 14/19 | 14/19 | 14/19 | 14/19 | |
|
Chilled Water Flow Rate |
m³/h | 5.6 | 8.4 | 11.2 | 14 | 16.8 | 22.5 | 28.1 | 33.7 | 42.1 | 42.1 | 70.2 | ||
|
Hot Water Temperature |
℃ | 40/35 | 40/35 | 40/35 | 40/35 | 40/35 | 40/35 | 40/35 | 40/35 | 40/35 | 40/35 | 40/35 | ||
|
Standard Static Pressure |
Hot Water Flow Rate |
m³/h | 4.4 | 6.6 | 8.8 | 11 | 13.3 | 17.7 | 22.1 | 26.5 | 33.1 | 44.2 | 55.0 | |
| Pressure Bearing Capacity | Mpa | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 | ||
| Water Resistance | kPa | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | ||
|
Connecting Pipe Size |
- | DN40 | DN50 | DN50 | DN65 | DN65 | DN65 | DN80 | DN80 | DN65 | DN80 | DN80 | ||
| High Static Pressure |
Static Pressure Range |
Pa | 150-350 | 150-250 | 150-200 | 150-250 | 150-350 | 150-500 | 150-200 | 150 | 150-500 | 150-200 | 150 | |
|
Installed Power |
kW | 8.44 | 9.24 | 10.64 | 16.11 | 16.11 | 27.12 | 27.12 | 34.22 | 54.24 | 54.24 | 68.44 | ||
| Noise | dB(A) | 60 | 61-62 | 62-63 | 62-64 | 64 | 64 | 65 | 65-66 | 67 | 67-68 | 68-70 | ||
|
Static Pressure Range |
Pa | 400-600 | 300-600 | 250-600 | 300-500 | 400-600 | 550-600 | 250-450 | 200-600 | 550-600 | 250-450 | 200-600 | ||
|
Installed Power |
kW | 8.84 | 9.94 | 11.44 | 16.11 | 17.11 | 28.62 | 28.62 | 36.22 | 57.24 | 57.24 | 72.44 | ||
| Noise | dB(A) | 61 | 61-62 | 63 | 63 | 64 | 64-65 | 65-66 | 67 | 68-69 | 69-71 | 72 | ||
|
Unit Dimensions |
Length | mm | 3200 | 3200 | 3200 | 3200 | 3200 | 3200 | 3200 | 3200 | 3200 | 3200 | 3200 | |
| Width | mm | 1140 | 1140 | 1140 | 1500 | 1500 | 2000 | 2360 | 2720 | 5000 | 5720 | 6440 | ||
| Height | mm | 2600 | 2600 | 2600 | 2800 | 2800 | 2800 | 2800 | 2800 | 2800 | 2800 | 2800 | ||
| Operating Weight | kg | 2330 | 2430 | 2530 | 2740 | 2840 | 3620 | 4400 | 5200 | 7240 | 8800 | 9900 | ||
|
Ventilation System |
Fan System | Centrifugal Fan | ||||||||||||
| Drive Mode | Belt Drive / Direct Drive | |||||||||||||
| Filtration Grade | Preliminary Efficiency (G4) | |||||||||||||