GMAC Series Free-Cooling Chiller

Designed for data center cooling, integrating oil-free, variable-speed magnetic-bearing centrifugal compressors, EC fans and free-cooling coils.

Variable-speed compressors adapt to changing loads, delivering efficient part-load operation and reducing cooling energy consumption.

Uses free cooling at suitable outdoor temperatures to reduce mechanical cooling demand and improve annual operating efficiency.

Uses R1234ze refrigerant and multiple independent refrigeration circuits, with power supply and control options tailored to project requirements.

Product Advantages

Oil-Free Magnetic-Bearing Technology

Oil-free, variable-speed magnetic-bearing centrifugal compressors reduce mechanical friction.

Adapts to changing loads to improve part-load efficiency.

Integrated Free Cooling

Free-cooling coils are integrated into the condenser module.

Reduces mechanical cooling demand when outdoor temperatures permit free cooling.

Efficient Heat Transfer and Control

High-efficiency heat exchangers work in coordination with EC fans.

Supports variable-flow operation and coordinated pump control to reduce pumping energy.

Multiple Independent Refrigeration Circuits

Limits the impact of a single-circuit failure on overall cooling operation.

Redundant capacity is configured to meet project loads and cooling continuity requirements.

Flexible Power and Control Options

Features low starting current and fast-restart capability.

Options include dual power inputs, an automatic transfer switch and ultracapacitors.

Oil-Free Magnetic Bearings

Efficient Variable-Speed Operation

Free Cooling

Uses Outdoor Air for Cooling

Efficient Heat Transfer

Optimizes Energy Use

Independent Circuits

Supports Redundancy

Power & Controls

Configurable to Project Needs

  • Oil-Free Magnetic Bearings
    Oil-Free Magnetic Bearings
  • Free Cooling
    Free Cooling
  • Efficient Heat Transfer
    Efficient Heat Transfer
  • Independent Circuits
    Independent Circuits
  • Power & Controls
    Power & Controls

Basic Parameters

R1234ze Free-Cooling Chiller GMAC250 GMAC400 GMAC500 GMAC650 GMAC800 GMAC950 GMAC1200 GMAC1400
Outdoor Air: 95°F
Fluid: 30% EG
EWT/LWT:
78.8°F / 68°F
Nominal cooling capacity (tons) 94 128 171 199 242 270 370 398
EER (Btu/Wh) 15.9 15.8 15.7 15.6 15.3 16.2 15.0 15.0
Power Input (kW) 101 138 177 212 261 278 424 471
(ZET), °F 47 47 50 50 50 51 50 48
Components No. of Compressors 2 2 3 3 3 3 4 4
No. of Refrigerant Circuits 2 2 3 3 3 3 4 4
Power Supply 460 V / 3 Ph / 60 Hz
Fans 6 8 12 14 16 20 22 22
Evaporator Shell-and-Tube
Condenser Finned Coil
Free-Cooling Free-Cooling Coil
Dimensions Length (in.) 136.2 177.6 260.2 301.6 342.9 425.6 466.9 466.9
Width (in.) 88.6 88.6 88.6 88.6 88.6 88.6 88.6 88.6
Height (in.) 109.8 109.8 109.8 109.8 109.8 109.8 109.8 109.8